SCD4X CO₂, Temperature and Relative Humidity Sensor¶
The scd4x
sensor platform allows you to use your Sensirion SCD4X CO₂
(datasheet) sensors with ESPHome.
The I²C Bus is required to be set up in your configuration for this sensor to work.
# Example configuration entry
sensor:
- platform: scd4x
co2:
name: "Workshop CO2"
temperature:
name: "Workshop Temperature"
humidity:
name: "Workshop Humidity"
Configuration variables:¶
co2 (Optional): The information for the CO₂ sensor.
All options from Sensor.
temperature (Optional): The information for the Temperature sensor.
All options from Sensor.
humidity (Optional): The information for the Humidity sensor.
All options from Sensor.
temperature_offset (Optional, float): The temperature offset can depend on various factors such as the SCD4x measurement mode, self-heating of close components, the ambient temperature and air flow. This variable allows the compensation of those effects by setting a temperature offset. Defaults to
4°C
.automatic_self_calibration (Optional, boolean): Whether to enable automatic self calibration (ASC). Defaults to
true
.ambient_pressure_compensation (Optional, int): Enable compensation of measured CO₂ values based on given ambient pressure in mBar.
altitude_compensation (Optional, int): Enable compensating deviations due to current altitude (in metres). Notice: setting altitude_compensation is ignored if ambient_pressure_compensation is set.
measurement_mode (Optional): Set measurement mode for scd4x.
periodic
: The sensor takes a new measurement every 5 seconds. This is the default mode.low_power_periodic
: The sensor takes a new measurement every 30 seconds. Make sureupdate_interval
is at least 30 seconds.single_shot
: A measurement is started in every update interval. A measurement takes 5 seconds. This mode is only available on scd41 and useful if low power consumption is required. The automatic self-calibration is optimized for single shot measurements performed every 5 minutes. To reduce noise levels, you can can perform several single shot measurements in a row and average the output values using a Sensor Filters.single_shot_rht_only
: A measurement is started in every update interval. A measurement takes 50 ms. Only humidity and temperature is measured. CO2 is reported as 0 ppm. This mode is only available on scd41 and useful if low power consumption is required.
ambient_pressure_compensation_source (Optional, ID): Set an external pressure sensor ID used for ambient pressure compensation. The pressure sensor must report pressure in hPa. the correction is applied before updating the state of the co2 sensor.
address (Optional, int): Manually specify the I²C address of the sensor. Defaults to
0x62
.update_interval (Optional, Time): The interval to check the sensor. Defaults to
60s
.
Actions:¶
perform_forced_calibration
Action¶
This action manually calibrates the sensor to the provided value in ppm. Operate the SCD4x in the operation mode later used in normal sensor operation (periodic measurement, low power periodic measurement or single shot) for > 3 minutes in an environment with homogenous and constant CO2 concentration before performing a forced recalibration. As of April 2022 the average fresh air Co² concentration is 419 ppm.
on_...:
then:
- scd4x.perform_forced_calibration:
value: 419 # outside average April 2022
id: my_scd41
value can also be a template, for example to define a Home Assistant calibration action:
api:
actions:
- action: calibrate_co2_value
variables:
co2_ppm: int
then:
- scd4x.perform_forced_calibration:
value: !lambda 'return co2_ppm;'
id: my_scd41
factory_reset
Action¶
This action triggers a factory reset of the sensor. Calibration settings are restored from factory settings.
on_...:
then:
- scd4x.factory_reset: my_scd41
Pressure compensation¶
A static ambient pressure value can be set with ambient_pressure_compensation or altitude_compensation. It can also be changed dynamically with lambdas using set_ambient_pressure_compensation(<mBar>), or by pointing ambient_pressure_compensation_source to a local pressure sensor.
Example with a local sensor¶
Note: remember your pressure sensor needs to output in mBar
sensor:
- platform: bme280
pressure:
name: "Ambient Pressure"
id: bme_pressure
- platform: scd4x
measurement_mode: low_power_periodic
ambient_pressure_compensation_source: bme_pressure
temperature_offset: 0
co2:
name: "CO2 level"
Example with a remote sensor¶
This example creates a service set_ambient_pressure that can be called from Home Assistant:
api:
actions:
- action: set_ambient_pressure
variables:
pressure_mbar: int
then:
- lambda: "id(my_scd41)->set_ambient_pressure_compensation(pressure_mbar);"
sensor:
- platform: scd4x
id: my_scd41
measurement_mode: low_power_periodic
temperature_offset: 0
co2:
name: "CO2 level"