MiCS 4514 Gas Sensor¶
This component exposes the different gas concentration sensors from the MiCS-4514. This is a differnet sensor than the MICS-4514 being sold on AliExpress.
Note
The sensor has a 3-minute warmup period where data is unreliable and ESPHome will only start publishing sensor values after this time. If the sensor was already powered only, such as if you restarted or updated your ESPHome device, then it will start publishing immediately.
The I²C Bus is required to be set up in your configuration for this sensor to work.
# Example configuration entry
sensor:
- platform: mics_4514
nitrogen_dioxide:
name: Nitrogen Dioxide
carbon_monoxide:
name: Carbon Monoxide
hydrogen:
name: Hydrogen
ethanol:
name: Ethanol
methane:
name: Methane
ammonia:
name: Ammonia
update_interval: 60s
Configuration variables:¶
nitrogen_dioxide (Optional): All options from Sensor
carbon_monoxide (Optional): All options from Sensor
hydrogen (Optional): All options from Sensor
ethanol (Optional): All options from Sensor
methane (Optional): All options from Sensor
ammonia (Optional): All options from Sensor
update_interval (Optional, Time): The interval to check the sensor. Defaults to
60s
.