Belling BL0940 Energy Monitor¶
Note
This page is incomplete and could some work. If you want to contribute, please read the contributing guide. This page is missing:
Images/screenshots/example configs of this device being used in action.
The bl0940
sensor platform allows you to use BL0940 energy monitors sensors with
ESPHome. These are used in some Tuya-devices (e.g. the power metering BW-SHP10)
The communication with this component is done via a UART.
You must therefore have a uart:
entry in your configuration with both the TX and RX pins set
to some pins on your board and the baud rate set to 4800 with 1 stop bit.
# Example configuration entry
uart:
id: uart_bus
tx_pin: TX
rx_pin: RX
baud_rate: 4800
stop_bits: 1
sensor:
- platform: bl0940
uart_id: uart_bus
voltage:
name: 'BL0940 Voltage'
current:
name: 'BL0940 Current'
power:
name: 'BL0940 Power'
energy:
name: 'BL0940 Energy'
internal_temperature:
name: 'BL0940 Internal temperature'
external_temperature:
name: 'BL0940 External temperature'
update_interval: 60s
Configuration variables:¶
voltage (Optional): The voltage value of the sensor in Volts. All options from Sensor.
current (Optional): The current value of the sensor in Amperes. All options from Sensor.
power (Optional): The (active) power value of the sensor in Watts. All options from Sensor.
energy (Optional): Use the voltage value of the sensor in kWh. All options from Sensor.
internal_temperature (Optional): The internal temperature value of the sensor in °C. All options from Sensor.
external_temperature (Optional): The external value of the sensor in °C. Often not connected and gives garbage data. All options from Sensor.
update_interval (Optional, Time): The interval to check the sensor. Defaults to
60s
.uart_id (Optional, ID): Manually specify the ID of the UART Component if you want to use multiple UART buses.