Atlas Scientific Peristaltic Pump¶
The ezo_pmp
component allows you to use an Atlas Scientific Peristaltic Pump with ESPHome.
Both the EZO-PMP (datasheet)
and EZO-PMP-L (datasheet) are supported.
The I²C Bus is required to be set up in your configuration for this sensor to work.
Note
This component will not be directly controllable in the Home Assistant front-end automatically because Home Assistant doesn’t have support for pumps. In order to control the pump from the frontend you will need to use templates to offer access to the actions you need. Please see Home Assistant Configuration.
ezo_pmp:
id: ezo_pmp
address: 103 # Default Address for the EZO-PMP.
update_interval: 60s
Configuration variables:
id (Required, ID): Specify the ID of the pump so that you can control it.
address (Optional, int): Specify the I²C address of the sensor. Defaults to 103.
update_interval (Optional, Time): The interval to check the sensor. Defaults to
60s
.
Sensors¶
Since the EZO-PMP offers a large number of sensors and each sensor needs to be polled individually, the code has been optimized not to update a sensor that is not defined in the config. If you need very quick updates from the pump (under 3 seconds) only enable the sensors that you actually need.
current_volume_dosed
¶
This sensor indicates the volume (in milliliters) that has been dosed in the currently running or last ran dosing command.
sensor:
- platform: ezo_pmp
current_volume_dosed:
id: current_volume_dosed
name: Current Volume Dosed
Configuration variables:
total_volume_dosed
¶
This sensor indicates total volume (in milliliters) that has been dosed since the last time the pump was turned on. Could be a negative number if the pump has been run in reverse.
sensor:
- platform: ezo_pmp
total_volume_dosed:
id: total_volume_dosed
name: Total Volume Dosed
Configuration variables:
absolute_total_volume_dosed
¶
This sensor indicates the absolute total volume (in milliliters) that has been dosed since the last time the pump was turned on.
sensor:
- platform: ezo_pmp
absolute_total_volume_dosed:
id: absolute_total_volume_dosed
name: Absolute Total Volume Dosed
Configuration variables:
last_volume_requested
¶
Indicates the total volume (in milliliters) that is being dosed (or was if the pump has already finished) by a dose Action. When using dosing actions that have a duration, the sensor will have the right calculation for total volume.
sensor:
- platform: ezo_pmp
last_volume_requested:
id: last_volume_requested
name: Last Volume Requested
Configuration variables:
max_flow_rate
¶
The pump provides its own calculation of the maximum flow rate it can provide (in ml/minute). Dosing requests that exceed this rate will fail. When using the Dose Continuously Action, this is the volume the pump will dose every minute. This value will get updated after the pump is calibrated (see ezo_pmp.set_calibration_volume Action).
sensor:
- platform: ezo_pmp
max_flow_rate:
id: max_flow_rate
name: Max Flow Rate
Configuration variables:
pump_voltage
¶
The current voltage of the power supply that powers the pump. Not to be confused with the voltage that powers the electronics on the pump.
sensor:
- platform: ezo_pmp
pump_voltage:
id: pump_voltage
name: Pump Voltage
Configuration variables:
Binary Sensors¶
pump_state
¶
Indicates if the pump is currently running or not.
binary_sensor:
- platform: ezo_pmp
pump_state:
id: pump_state
name: Pump State
Configuration variables:
id (Optional, ID): Set the ID of this sensor for use in lambdas.
All other options from Binary Sensor.
is_paused
¶
Indicates if a dosing action is currently paused.
binary_sensor:
- platform: ezo_pmp
is_paused:
id: is_paused
name: Is Paused
Configuration variables:
id (Optional, ID): Set the ID of this sensor for use in lambdas.
All other options from Binary Sensor.
Text Sensors¶
dosing_mode
¶
Indicates the dosing mode the pump is currently running as. Can be any of Volume, Volume/Time, Constant Flow Rate, Continuous, None.
text_sensor:
- platform: ezo_pmp
dosing_mode:
id: dosing_mode
name: Dosing Mode
Configuration variables:
id (Optional, ID): Set the ID of this sensor for use in lambdas.
All other options from Text Sensor.
calibration_status
¶
Indicates calibration status of the pump. Can be any of Fixed Volume, Volume/Time, Fixed Volume & Volume/Time or Uncalibrated.
text_sensor:
- platform: ezo_pmp
calibration_status:
id: calibration_status
name: Calibration Status
Configuration variables:
id (Optional, ID): Set the ID of this sensor for use in lambdas.
All other options from Text Sensor.
Actions¶
ezo_pmp.dose_continuously
Action¶
Use this action in an automations to have the peristaltic pump dose continuously at the Maximum Flow Rate. The pump will automatically stop after 20 days of running in continuous mode.
on_...:
then:
- ezo_pmp.find:
id: ezo_pmp
Configuration options:
id (Required, ID): The ID of the pump.
ezo_pmp.dose_volume
Action¶
Use this action in an automations to have the peristaltic pump dose an specific volume (in milliliters) at the Maximum Flow Rate. If the volume is negative the pump will run backwards.
on_...:
then:
- ezo_pmp.dose_volume:
id: ezo_pmp
volume: 10
# Templated
- ezo_pmp.dose_volume:
id: ezo_pmp
volume: !lambda |-
return id(some_volume_sensor).state;
Configuration options:
id (Required, ID): The ID of the pump.
volume (Required, float, templatable): The volume to dose in milliliters. If negative, pump will run in reverse.
ezo_pmp.dose_volume_over_time
Action¶
Use this action in an automations to have the peristaltic pump dose an specific volume
(in milliliters)
over the provided duration
(in minutes). At the end of the time period the pump will have dosed the specified volume
.
If the volume is negative the pump will run backwards.
on_...:
then:
- ezo_pmp.dose_volume_over_time:
id: ezo_pmp
volume: 23.4
duration: 2
# Templated
- ezo_pmp.dose_volume_over_time:
id: ezo_pmp
volume: !lambda |-
return id(some_volume_sensor).state;
duration: !lambda |-
return id(some_duration_sensor).state;
Configuration options:
id (Required, ID): The ID of the pump.
volume (Required, float, templatable): The volume to dose in milliliters. If negative, pump will run in reverse.
duration (Required, int, templatable): The time (in minutes) the pump will take to dose the volume requested.
ezo_pmp.dose_with_constant_flow_rate
Action¶
Use this action in an automations to have the peristaltic pump dose an specific volume
(in milliliters) every minute
for the provided duration
(in minutes). At the end of the time period the pump will have dosed the specified volume
times the duration
.
If the volume is negative the pump will run backwards.
on_...:
then:
- ezo_pmp.dose_with_constant_flow_rate:
id: ezo_pmp
volume_per_minute: 10.2
duration: 2
# Templated
- ezo_pmp.dose_with_constant_flow_rate:
id: ezo_pmp
volume_per_minute: !lambda |-
return id(some_volume_sensor).state;
duration: !lambda |-
return id(some_duration_sensor).state;
Configuration options:
id (Required, ID): The ID of the pump.
volume_per_minute (Required, float, templatable): The volume to dose in milliliters every minute. If negative, pump will run in reverse.
duration (Required, int, templatable): The time (in minutes) the pump will dose the volume requested every minute.
ezo_pmp.pause_dosing
Action¶
Use this action to pause a Dosing command that was previously issued. To determine if the dosing is paused or not, you can use the Is Paused sensor. If the pump is currently paused, issuing this action again will unpause it.
on_...:
then:
- ezo_pmp.pause_dosing:
id: ezo_pmp
Configuration options:
id (Required, ID): The ID of the pump.
ezo_pmp.stop_dosing
Action¶
Use this action to stop the current Dosing command.
on_...:
then:
- ezo_pmp.stop_dosing:
id: ezo_pmp
Configuration options:
id (Required, ID): The ID of the pump.
ezo_pmp.clear_total_volume_dosed
Action¶
Clear the values of the Current Volume Dosed, Total Volume Dosed and Absolute Total Volume Dosed sensors.
on_...:
then:
- ezo_pmp.clear_total_volume_dosed:
id: ezo_pmp
Configuration options:
id (Required, ID): The ID of the pump.
ezo_pmp.set_calibration_volume
Action¶
Use this action to calibrate the peristaltic pump. The EZO-PMP needs two forms of calibration: absolute volume and volume over time. You can check the calibration status by using the Calibration Status sensor. For the procedure on calibrating the pump check the datasheet.
on_...:
then:
- ezo_pmp.set_calibration_volume:
id: ezo_pmp
volume: 10.01
# Templated
- ezo_pmp.set_calibration_volume:
id: ezo_pmp
volume: !lambda |-
return id(some_volume_sensor).state;
Configuration options:
id (Required, ID): The ID of the pump.
volume (Required, float, templatable): The volume measured as part of the calibration process.
ezo_pmp.clear_calibration
Action¶
Clear the calibration values stored in the pump. You can check the calibration status by using the Calibration Status sensor.
on_...:
then:
- ezo_pmp.clear_calibration:
id: ezo_pmp
Configuration options:
id (Required, ID): The ID of the pump.
ezo_pmp.find
Action¶
Use this action to make the LED on the Pump control board to blink for a minute. The pump will not respond to any other action while the LED is blinking.
on_...:
then:
- ezo_pmp.find:
id: ezo_pmp
Configuration options:
id (Required, ID): The ID of the pump.
ezo_pmp.change_i2c_address
Action¶
Changes the i2c address of the pump to the provided value. After the address is changed you must upload a new version of the ESPHome firmware with the updated I2C address for the pump to work.
on_...:
then:
- ezo_pmp.change_i2c_address:
id: ezo_pmp
address: 100
Configuration options:
id (Required, ID): The ID of the pump.
address (Required, int, templatable): The new I2C address for the pump.
Home Assistant Configuration¶
In order to provide control of the pump from the home assistant frontend it is important to expose the actions as components that have UI rendering. This could be done using templates in ESPHome. Here is an example using a Template Button and Template Number to dose a certain volume over time.
i2c:
ezo_pmp:
id: ezo_pmp
number:
- platform: template
id: volume
name: "Volume"
optimistic: true
min_value: 0
max_value: 100
step: 0.01
- platform: template
id: duration
name: "Duration"
optimistic: true
min_value: 0
max_value: 100
step: 1
button:
- platform: template
name: "Dose Over Time"
on_press:
- ezo_pmp.dose_volume_over_time:
id: ezo_pump
volume: !lambda |-
return id(volume).state;
duration: !lambda |-
return id(duration).state;
lambda calls¶